PCC — power control centres

Main distribution boards with structured busbar and cable management.

Bus bracing, clearances and routing are settled at drawing stage and verified at the works before dispatch.

  • Fabricated and tested at Faridabad works
  • Continuous busbar chamber, full-height cable alley
SHOT NEEDEDPrimary product photograph for pcc panels — three-quarter view at the works, full frame, even light
SPECIFICATION
Specification. 2 of 7 values are documented; the rest are set per order or unpublished.
Standard IS/IEC 61439-2 Source: Company Profile 2026; existing site copy
Incomer and outgoing ratings To your requirement Drawn from your feeder schedule.
Busbar rating and bracing To your requirement Settled at drawing stage against your fault level.
Enclosure and ingress rating To your requirement Selected against the installation environment.
Construction Continuous busbar chamber, full-height cable alley Busbar chamber and cable alleys are labelled as separate vertical compartments on the photographed board.Source: Existing site copy, carried from Company Profile 2026; corroborated by compartment labels legible in works photograph
Form of separation Not published — no Form designation has been supplied for publication. Confirmed against your drawing at enquiry.
Short-circuit withstand Not published — no type-test evidence is on file.

Evidence

  • Thirteen activities are named in the scope of ISO 9001:2015 certificate E20250830652: LT control panels; MCC; PCC; PLC panels; VFD panels; power factor panels (APFCR); control transformer; distribution transformers (dry and oil); on-line UPS; compact sub-station; on/off-line solar system; electrical turnkey projects; electrical consultant/contractor and electrical worksE20250830652Royal Assessments Pvt. Ltd., accredited through EGACOpen document
  • ISO 9001:2015 quality management certificateE20250830652Royal Assessments Pvt. Ltd., accredited through EGACOpen document
  • Power control centres built to IS/IEC 61439-2IS/IEC 61439-2Referenced standard

At the works

SHOT NEEDED
Front elevation of a floor-standing LT panel in three vertical sections: a control section with pushbuttons and a digital relay, a central busbar chamber, and a right-hand section of switch-disconnector compartments above a power factor correction section with staged indication.
Main LT panel combining AMF and APFC(R) in one board. Busbar chamber and cable alleys are labelled as separate vertical compartments; the power factor controller sits at the door of the correction sectionMAIN LT WITH AMF & APFCR — read from the designation label, not a range
SHOT NEEDED
SHOT NEEDED
SHOT NEEDED
SHOT NEEDED
SHOT NEEDED
SHOT NEEDED
SHOT NEEDED
A multi-section LT panel lineup indoors under a metal roof, indicator lamps lit across several compartments, rotary switches and ventilation louvres on the doors, with a pedestal fan alongside.
Lineup energised at the works with indication live. Works testing precedes dispatch on every assembly.
A large multi-section LT panel lineup standing on a concrete plinth under a shed roof, doors closed, with metering and indication across the upper fascia and rotary selectors below.
Standing on its plinth under cover. Metering and indication run across the upper fascia.
Front elevation of a finished LT panel, doors closed, with a metering window at the top, three indicator lamps and a column of rotary selector switches down the compartment doors.
Finished front elevation before dispatch. Metering at the top, rotary selectors on each compartment door.
A shrink-wrapped floor-standing panel with an orange-fronted control section on top, slung from a hydraulic crane and moving down a walled lane away from the works.
Wrapped for transport and lifted out by crane. The orange control section on top carries the indication and metering fascia.

Documents

  • Panel general arrangement drawing Drawn to your feeder schedule and site constraint, issued for approval before manufacture.
    Request Drawn to your feeder schedule and site constraint.
  • As-built panel schematic As-built schematic, ferruled to match the panel, handed over with the equipment.
    Request Issued for the assembly you are specifying, against the enquiry.
  • Operation and maintenance manual Issued with the plant, covering routine maintenance intervals and torque values.
    Request Issued with the plant it documents.